Parent Directory | Revision Log
First CVS release of tracker ground software (R3v02)
1 | Alignment parameters obtained starting from the alignment parameters of the |
2 | colums (from test beam), by means of ground muons. |
3 | |
4 | STEP1 |
5 | ----- |
6 | Alignment parameters are first corrected for the AVERAGE shift (NB only |
7 | TRASLATIONS) of the PLANE (evaluated from residual distributions, obtained by |
8 | using alignment parameters of the colums). |
9 | |
10 | STEP2 |
11 | ----- |
12 | Muon tracks crossing two different colums were selected, and parameters were |
13 | corrected for the relative misalignment of the colums. |
ViewVC Help | |
Powered by ViewVC 1.1.23 |