| 1 |
|
| 2 |
|
| 3 |
This directory contains all the parameters needed for tracker data reduction. |
| 4 |
|
| 5 |
During the compilation of "level2.exe" program, these auxiliary files are moved |
| 6 |
in the directory "bin-aux", which is created together with the executable. |
| 7 |
The "official" files (that is those that are copied in "bin-aux") for 2005 data |
| 8 |
are the following: |
| 9 |
|
| 10 |
align_param/parameters_l*s*.dat |
| 11 |
align_param/mech_pos.dat |
| 12 |
|
| 13 |
eta_param/eta*_binning.dat |
| 14 |
eta_param/eta*_bin*_l*.dat |
| 15 |
|
| 16 |
charge_param/charge-l*.dat |
| 17 |
|
| 18 |
field_meas/*.rz |
| 19 |
|
| 20 |
(NB! The program "level2-2003.exe" is associated with different parameters sets, |
| 21 |
labelled with "2003") |
| 22 |
|
| 23 |
All the other files and directory are different versions of the same parameters, |
| 24 |
that are kept in some case just for historical reasons. |
| 25 |
It follows a short description of the data. |
| 26 |
|
| 27 |
============================================================================== |
| 28 |
- align_param-COLONNE |
| 29 |
Alignment parameters for the coloumns, from CERN beam test 2003 |
| 30 |
|
| 31 |
- align_param-2003 |
| 32 |
Same alignment parameters as align_param-COLONNE, associated with the new |
| 33 |
mechanical positions |
| 34 |
|
| 35 |
- align_param-OTTICI |
| 36 |
Alignment parameters for the whole tracker, using the optical measurements to |
| 37 |
fix the relative positions of sensors in the two reference plane. |
| 38 |
The procedure was applied to test 2003 data, and compared with the previous. |
| 39 |
The result seems not good. It may be due to a variation of the sensor position |
| 40 |
after inserting the planes in the tower. |
| 41 |
|
| 42 |
- align_param-MUONI |
| 43 |
First set of alignment parameters obtained with muon, from Rome 2005 runs. |
| 44 |
The idea is to correct the parameters for the columns, from test 2003, by |
| 45 |
varying the relative positions of the column (by means of tarcks that cross |
| 46 |
the columns). |
| 47 |
The result is not satisfactory. |
| 48 |
The reason is that meanwhile we realized that from 2003 to 2005 the planes |
| 49 |
moved... becouse of the vibration test. |
| 50 |
|
| 51 |
- align_param-SHIFTS-then-MUONI |
| 52 |
We then tried to apply the procedure above, after having corrected the relative |
| 53 |
positions of the planes for x and y translations, evaluated from the residual |
| 54 |
distributions. |
| 55 |
|
| 56 |
- align_param-COLONNE-shift2 |
| 57 |
Since also the procedure above does not convince, we first corrected the |
| 58 |
parameters from the shifts only (better evaluated) and see what happens. |
| 59 |
However, even after the correction, the residual distributions are not centered. |
| 60 |
|
| 61 |
- align_param-COLONNE-shift3 |
| 62 |
The correction above was iterated. |
| 63 |
|
| 64 |
- align_param-COLONNE-RIALIGN |
| 65 |
The column have been realigned, by using the measured muon momentum corrected |
| 66 |
for the estimated deflection offset. |
| 67 |
|
| 68 |
- align_param-COLONNE-RIALIGN2 |
| 69 |
The column have been realigned, by using the measured muon momentum corrected |
| 70 |
for the estimated deflection offset. |
| 71 |
The alignment was repeated to get correct error estimates for all the columns. |
| 72 |
Now residuals and charge ratio seems to be ok and the offset in eta is removed. |
| 73 |
|
| 74 |
- align_param-COSMIC |
| 75 |
Alignment of the whole spectrometer using cosmic muons, strarting from the |
| 76 |
align_param-COLONNE-RIALIGN2 for the single columns |
| 77 |
|
| 78 |
============================================================================== |
| 79 |
|
| 80 |
- mech_pos.dat-old |
| 81 |
- mech_pos.dat-new |
| 82 |
Mechanical position of the sensors. In the old version the tickness of the |
| 83 |
carbon stiffners was wrong. |
| 84 |
NB!! To each set of allignment parameters must be associated the proper |
| 85 |
mechanical positions (old-old new-new ... but for some exceptions) |
| 86 |
|
| 87 |
============================================================================== |
| 88 |
|
| 89 |
- charge_param-2003 |
| 90 |
- eta_param-2003 |
| 91 |
Charge correlation parameters and eta2 correction functions, evaluated from test |
| 92 |
2003 data. In this set of parameters not all the angular bins are populated. |
| 93 |
|
| 94 |
============================================================================== |
| 95 |
|
| 96 |
- data-card.dat |
| 97 |
This file is needed for charge correlation calibration. |