1
2
3 This directory contains all the parameters needed for tracker data reduction.
4
5 During the compilation of "level2.exe" program, these auxiliary files are moved
6 in the directory "bin-aux", which is created together with the executable.
7 The "official" files (that is those that are copied in "bin-aux") for 2005 data
8 are the following:
9
10 align_param/parameters_l*s*.dat
11 align_param/mech_pos.dat
12
13 eta_param/eta*_binning.dat
14 eta_param/eta*_bin*_l*.dat
15
16 charge_param/charge-l*.dat
17
18 field_meas/*.rz
19
20 (NB! The program "level2-2003.exe" is associated with different parameters sets,
21 labelled with "2003")
22
23 All the other files and directory are different versions of the same parameters,
24 that are kept in some case just for historical reasons.
25 It follows a short description of the data.
26
27 ==============================================================================
28 - align_param-COLONNE
29 Alignment parameters for the coloumns, from CERN beam test 2003
30
31 - align_param-2003
32 Same alignment parameters as align_param-COLONNE, associated with the new
33 mechanical positions
34
35 - align_param-OTTICI
36 Alignment parameters for the whole tracker, using the optical measurements to
37 fix the relative positions of sensors in the two reference plane.
38 The procedure was applied to test 2003 data, and compared with the previous.
39 The result seems not good. It may be due to a variation of the sensor position
40 after inserting the planes in the tower.
41
42 - align_param-MUONI
43 First set of alignment parameters obtained with muon, from Rome 2005 runs.
44 The idea is to correct the parameters for the columns, from test 2003, by
45 varying the relative positions of the column (by means of tarcks that cross
46 the columns).
47 The result is not satisfactory.
48 The reason is that meanwhile we realized that from 2003 to 2005 the planes
49 moved... becouse of the vibration test.
50
51 - align_param-SHIFTS-then-MUONI
52 We then tried to apply the procedure above, after having corrected the relative
53 positions of the planes for x and y translations, evaluated from the residual
54 distributions.
55
56 - align_param-COLONNE-shift2
57 Since also the procedure above does not convince, we first corrected the
58 parameters from the shifts only (better evaluated) and see what happens.
59 However, even after the correction, the residual distributions are not centered.
60
61 - align_param-COLONNE-shift3
62 The correction above was iterated.
63
64 - align_param-COLONNE-RIALIGN
65 The column have been realigned, by using the measured muon momentum corrected
66 for the estimated deflection offset.
67
68 - align_param-COLONNE-RIALIGN2
69 The column have been realigned, by using the measured muon momentum corrected
70 for the estimated deflection offset.
71 The alignment was repeated to get correct error estimates for all the columns.
72 Now residuals and charge ratio seems to be ok and the offset in eta is removed.
73
74 - align_param-COSMIC
75 Alignment of the whole spectrometer using cosmic muons, strarting from the
76 align_param-COLONNE-RIALIGN2 for the single columns
77
78 ==============================================================================
79
80 - mech_pos.dat-old
81 - mech_pos.dat-new
82 Mechanical position of the sensors. In the old version the tickness of the
83 carbon stiffners was wrong.
84 NB!! To each set of allignment parameters must be associated the proper
85 mechanical positions (old-old new-new ... but for some exceptions)
86
87 ==============================================================================
88
89 - charge_param-2003
90 - eta_param-2003
91 Charge correlation parameters and eta2 correction functions, evaluated from test
92 2003 data. In this set of parameters not all the angular bins are populated.
93
94 ==============================================================================
95
96 - data-card.dat
97 This file is needed for charge correlation calibration.