1 |
pam-fi |
1.1 |
|
2 |
|
|
|
3 |
|
|
This directory contains all the parameters needed for tracker data reduction. |
4 |
|
|
|
5 |
|
|
During the compilation of "level2.exe" program, these auxiliary files are moved |
6 |
|
|
in the directory "bin-aux", which is created together with the executable. |
7 |
|
|
The "official" files (that is those that are copied in "bin-aux") for 2005 data |
8 |
|
|
are the following: |
9 |
|
|
|
10 |
|
|
align_param/parameters_l*s*.dat |
11 |
|
|
align_param/mech_pos.dat |
12 |
|
|
|
13 |
|
|
eta_param/eta*_binning.dat |
14 |
|
|
eta_param/eta*_bin*_l*.dat |
15 |
|
|
|
16 |
|
|
charge_param/charge-l*.dat |
17 |
|
|
|
18 |
|
|
field_meas/*.rz |
19 |
|
|
|
20 |
|
|
(NB! The program "level2-2003.exe" is associated with different parameters sets, |
21 |
|
|
labelled with "2003") |
22 |
|
|
|
23 |
|
|
All the other files and directory are different versions of the same parameters, |
24 |
|
|
that are kept in some case just for historical reasons. |
25 |
|
|
It follows a short description of the data. |
26 |
|
|
|
27 |
|
|
============================================================================== |
28 |
|
|
- align_param-COLONNE |
29 |
|
|
Alignment parameters for the coloumns, from CERN beam test 2003 |
30 |
|
|
|
31 |
|
|
- align_param-2003 |
32 |
|
|
Same alignment parameters as align_param-COLONNE, associated with the new |
33 |
|
|
mechanical positions |
34 |
|
|
|
35 |
|
|
- align_param-OTTICI |
36 |
|
|
Alignment parameters for the whole tracker, using the optical measurements to |
37 |
|
|
fix the relative positions of sensors in the two reference plane. |
38 |
|
|
The procedure was applied to test 2003 data, and compared with the previous. |
39 |
|
|
The result seems not good. It may be due to a variation of the sensor position |
40 |
|
|
after inserting the planes in the tower. |
41 |
|
|
|
42 |
|
|
- align_param-MUONI |
43 |
|
|
First set of alignment parameters obtained with muon, from Rome 2005 runs. |
44 |
|
|
The idea is to correct the parameters for the columns, from test 2003, by |
45 |
|
|
varying the relative positions of the column (by means of tarcks that cross |
46 |
|
|
the columns). |
47 |
|
|
The result is not satisfactory. |
48 |
|
|
The reason is that meanwhile we realized that from 2003 to 2005 the planes |
49 |
|
|
moved... becouse of the vibration test. |
50 |
|
|
|
51 |
|
|
- align_param-SHIFTS-then-MUONI |
52 |
|
|
We then tried to apply the procedure above, after having corrected the relative |
53 |
|
|
positions of the planes for x and y translations, evaluated from the residual |
54 |
|
|
distributions. |
55 |
|
|
|
56 |
|
|
- align_param-COLONNE-shift2 |
57 |
|
|
Since also the procedure above does not convince, we first corrected the |
58 |
|
|
parameters from the shifts only (better evaluated) and see what happens. |
59 |
|
|
However, even after the correction, the residual distributions are not centered. |
60 |
|
|
|
61 |
|
|
- align_param-COLONNE-shift3 |
62 |
|
|
The correction above was iterated. |
63 |
|
|
|
64 |
|
|
- align_param-COLONNE-RIALIGN |
65 |
|
|
The column have been realigned, by using the measured muon momentum corrected |
66 |
|
|
for the estimated deflection offset. |
67 |
|
|
|
68 |
|
|
- align_param-COLONNE-RIALIGN2 |
69 |
|
|
The column have been realigned, by using the measured muon momentum corrected |
70 |
|
|
for the estimated deflection offset. |
71 |
|
|
The alignment was repeated to get correct error estimates for all the columns. |
72 |
|
|
Now residuals and charge ratio seems to be ok and the offset in eta is removed. |
73 |
|
|
|
74 |
|
|
- align_param-COSMIC |
75 |
|
|
Alignment of the whole spectrometer using cosmic muons, strarting from the |
76 |
|
|
align_param-COLONNE-RIALIGN2 for the single columns |
77 |
|
|
|
78 |
|
|
============================================================================== |
79 |
|
|
|
80 |
|
|
- mech_pos.dat-old |
81 |
|
|
- mech_pos.dat-new |
82 |
|
|
Mechanical position of the sensors. In the old version the tickness of the |
83 |
|
|
carbon stiffners was wrong. |
84 |
|
|
NB!! To each set of allignment parameters must be associated the proper |
85 |
|
|
mechanical positions (old-old new-new ... but for some exceptions) |
86 |
|
|
|
87 |
|
|
============================================================================== |
88 |
|
|
|
89 |
|
|
- charge_param-2003 |
90 |
|
|
- eta_param-2003 |
91 |
|
|
Charge correlation parameters and eta2 correction functions, evaluated from test |
92 |
|
|
2003 data. In this set of parameters not all the angular bins are populated. |
93 |
|
|
|
94 |
|
|
============================================================================== |
95 |
|
|
|
96 |
|
|
- data-card.dat |
97 |
|
|
This file is needed for charge correlation calibration. |