1 |
# |
# |
2 |
# $Id: v_100.txt,v 3.16 2006/10/12 11:11:21 pam-ba Exp $ |
# $Id: v_100.txt,v 3.17 2006/10/13 16:36:59 pam-ba Exp $ |
3 |
# |
# |
4 |
# $Log: v_100.txt,v $ |
# $Log: v_100.txt,v $ |
5 |
|
# Revision 3.17 2006/10/13 16:36:59 pam-ba |
6 |
|
# Added a new material, the cadmium, for ND |
7 |
|
# |
8 |
# Revision 3.16 2006/10/12 11:11:21 pam-ba |
# Revision 3.16 2006/10/12 11:11:21 pam-ba |
9 |
# ND geometry updated. |
# ND geometry updated. |
10 |
# |
# |
67 |
#CMZ : 1.00/01 28/11/95 18.51.23 by Francesco Cafagna |
#CMZ : 1.00/01 28/11/95 18.51.23 by Francesco Cafagna |
68 |
#-- Author : Francesco Cafagna 28/11/95 |
#-- Author : Francesco Cafagna 28/11/95 |
69 |
|
|
70 |
|
November 2006, Bari |
71 |
|
|
72 |
|
TOF POSITIONS DEFINITELY UPDATED: |
73 |
|
S2 and S1 have been positioned again, after the simulation of the top plate. |
74 |
|
Before now, the positions were put ad hoc based on the positions given by |
75 |
|
Sergio Ricciarini in the document 'Main geometrical parameters of the PAMELA |
76 |
|
sub-detectors' released by O. Adriani, L. Bonechi, E. Mocchiutti and |
77 |
|
S. Ricciarini on the 20th of December 2005.. These positions were |
78 |
|
lightly approximated. |
79 |
|
|
80 |
|
ND GEOMETRY COMPLETED. |
81 |
|
The He3 and the polyethylene (CH2) have been added to fill |
82 |
|
the volumes NDTI and NDPB in the neutron detector. Leonov gave us the |
83 |
|
details of these materials. |
84 |
|
|
85 |
|
TOP PLATE GEOMETRY ADDED. |
86 |
|
The top plate geometry has been simulated as a N2 box that has the same |
87 |
|
dimensions of CATA. Inside it, at the right positions, there are S2 and CATA. |
88 |
|
The real top plate is a rectangular window having a thickness of 0.5 cm |
89 |
|
(volume TPTL emptied by the volume TPCV). This volume is filled with a mixture |
90 |
|
of titanium (90%), aluminum (6%) and vanadium (4%). Other parts of titanium |
91 |
|
are the four volumes TPTU, which are positioned at the corners of TPTL at the |
92 |
|
same height of CATA, and the four volumes TPTM, which are positioned at the |
93 |
|
corners of TPTL, at the same height of S2. |
94 |
|
The geometry of the top plate is based on a simplified version of the CAD |
95 |
|
drawings. |
96 |
|
|
97 |
October 2006, Bari |
October 2006, Bari |
98 |
|
|
99 |
The geometry of the neutron detector has been updated. Some dimensions of some |
The geometry of the neutron detector has been updated. Some dimensions of some |
100 |
volumes have been corrected while the aluminum cover and the aluminum boxes to |
volumes have been corrected and the aluminum cover and the aluminum boxes to |
101 |
put the cables have been added. A new material, the cadmium, has been also |
put the cables have been added. A new material, the cadmium, has been also |
102 |
defined. |
defined. |
103 |
|
|