/[PAMELA software]/gpamela/history/v_100.txt
ViewVC logotype

Diff of /gpamela/history/v_100.txt

Parent Directory Parent Directory | Revision Log Revision Log | View Patch Patch

revision 3.15 by pam-ba, Mon Oct 2 11:17:30 2006 UTC revision 3.23 by cafagna, Thu Nov 30 13:22:35 2006 UTC
# Line 1  Line 1 
1  #  #
2  # $Id: v_100.txt,v 3.14 2006/06/30 15:38:16 pam-ba Exp $  # $Id: v_100.txt,v 3.22 2006/11/28 11:43:41 pam-ba Exp $
3  #  #
4  # $Log: v_100.txt,v $  # $Log: v_100.txt,v $
5    # Revision 3.22  2006/11/28 11:43:41  pam-ba
6    # History modified
7    #
8    # Revision 3.21  2006/11/28 10:26:15  pam-ba
9    # S3 positioning completed
10    #
11    # Revision 3.20  2006/11/16 18:45:29  pam-ba
12    # Simulated an aluminum container for S4
13    #
14    # Revision 3.19  2006/11/16 12:01:13  pam-ba
15    # S4 dimensions corrected.
16    #
17    # Revision 3.18  2006/11/10 11:39:35  pam-ba
18    # S2 and S1 z-positions corrected, He3 and plystyrene mixture added, Top Plate geometry simulated and titanium mixture added.
19    #
20    # Revision 3.17  2006/10/13 16:36:59  pam-ba
21    # Added a new material, the cadmium, for ND
22    #
23    # Revision 3.16  2006/10/12 11:11:21  pam-ba
24    # ND geometry updated.
25    #
26    # Revision 3.15  2006/10/02 11:17:30  pam-ba
27    # NDET 'SPHE' data card meaning changed. Now it eliminates the whole PAMELA container.
28    #
29  # Revision 3.14  2006/06/30 15:38:16  pam-ba  # Revision 3.14  2006/06/30 15:38:16  pam-ba
30  # S22 and S12 heights positioned in GPAMELA at the nominal heights in PAMELA (see document: Main geometrical parameters of the PAMELA sub-detectors, 20 December 2005)  # S22 and S12 heights positioned in GPAMELA at the nominal heights in PAMELA (see document: Main geometrical parameters of the PAMELA sub-detectors, 20 December 2005)
31  #  #
# Line 58  Line 82 
82  #CMZ :  1.00/01 28/11/95  18.51.23  by  Francesco Cafagna  #CMZ :  1.00/01 28/11/95  18.51.23  by  Francesco Cafagna
83  #-- Author :    Francesco Cafagna   28/11/95  #-- Author :    Francesco Cafagna   28/11/95
84    
85    30 November 2006, Bari F. Cafagna
86    
87    BUG FIXED
88    
89       For some reason there was a conflict using FLUKA and the GARFILD
90       interface for the TRD. The file TRD_ATT.TXT was treated as flukaerr
91       file by the compiler. It is not clear why. The code was correct,
92       the logical units and names were not inconflict, but the compiler
93       assigned to them the same internal number. It may be a problem
94       related to the optimization phase. I did close the file just after
95       the read-out in GPDAT.F and commented out the closing in UGLAST.F
96    
97    
98    
99    November 2006, Bari
100    
101    
102    S4 GEOMETRY UPDATED:
103    The x and y dimensions have been corrected because they were wrong.
104    A container of aluminum has been added having walls of thickness equal
105    to 0.1 cm.  
106    
107    TOF POSITIONS DEFINITELY UPDATED:
108    S2 and S1 have been positioned again, after the simulation of the top plate.
109    Before now, the positions were put by hand based on the positions given by
110    Sergio Ricciarini in the document 'Main geometrical parameters of the PAMELA
111    sub-detectors' released by O. Adriani, L. Bonechi, E. Mocchiutti and
112    S. Ricciarini on the 20th of December 2005.. These positions were
113    lightly approximated because the thicknesses of the mylar and of the glue were
114    not considered in that document. Also the height of S3 has been modified as
115    suggested from the Naples PAMELA collaborators.
116    
117    ND GEOMETRY COMPLETED.
118    The He3 and the polyethylene (CH2) have been added to fill
119    the volumes NDTI and NDPB in the neutron detector. Leonov gave us the
120    details of these materials.
121    
122    TOP PLATE GEOMETRY ADDED.
123    The top plate geometry has been simulated as a rectangular window filled
124    with a mixture of titanium (90%), aluminum (6%) and vanadium (4%). It has been
125    put in a N2 box having the same planar dimensions of CATA. In this box there
126    are also S2 and CATA at the right positions. Then the top plate geometry has
127    been completed with other eight small volumes of titanium positioned at the
128    corners of the N2 box. Four of them are at the same height of CATA, the
129    other four are at the same height of S2. The simulated geometry of the top
130    plate is based on a simplified version of the CAD drawings.
131    
132    October 2006, Bari
133    
134    The geometry of the neutron detector has been updated. Some dimensions of some
135    volumes have been corrected and the aluminum cover and the aluminum boxes to
136    put the cables have been added. A new material, the cadmium, has been also
137    defined.
138    
139  September 2006, Bari  September 2006, Bari
140    
141  SPHE and ND data card bugs fixed: the definition of the ND data card,  SPHE and ND data card bugs fixed: the definition of the ND data card,

Legend:
Removed from v.3.15  
changed lines
  Added in v.3.23

  ViewVC Help
Powered by ViewVC 1.1.23