/[PAMELA software]/gpamela/history/v_100.txt
ViewVC logotype

Diff of /gpamela/history/v_100.txt

Parent Directory Parent Directory | Revision Log Revision Log | View Patch Patch

revision 3.5 by pamela, Tue Apr 6 10:33:46 2004 UTC revision 3.14 by pam-ba, Fri Jun 30 15:38:16 2006 UTC
# Line 1  Line 1 
1  #  #
2  # $Id: v_100.txt,v 3.4 2003/12/17 11:32:50 pamela Exp $  # $Id: v_100.txt,v 3.13 2006/06/05 13:56:17 pamela Exp $
3  #  #
4  # $Log: v_100.txt,v $  # $Log: v_100.txt,v $
5    # Revision 3.13  2006/06/05 13:56:17  pamela
6    # Gigantic resonance added for gamma enetering in the calorimeter absorber
7    #
8    # Revision 3.12  2006/05/18 10:52:32  pam-ba
9    # TOF geometry completed and a new material, the polystyrene (density 35 g/l), added
10    #
11    # Revision 3.11  2006/05/11 23:53:15  cafagna
12    # More bugs fixed in the CALO ntple structure filling
13    #
14    # Revision 3.10  2006/04/10 11:07:43  cafagna
15    # GEN data card updated, ZDGEN added
16    #
17    # Revision 3.9  2005/12/14 03:34:40  cafagna
18    # An update of the history and inform readme files.
19    #
20    # Revision 3.8  2005/12/14 03:16:08  cafagna
21    # Neutron detector added. Geometry and GPCALOR package
22    #
23    # Revision 3.7  2005/10/18 08:24:35  cafagna
24    # History updated
25    #
26    # Revision 3.6  2005/07/25 11:53:21  cafagna
27    # Several updates. See history for details
28    #
29    # Revision 3.5  2004/04/06 10:33:46  pamela
30    # NON-REPRODUCIBILITY problem of a GPAMELA RUN fixed; bug found and fixed filling in the hit structure of the calorimeter
31    #
32  # Revision 3.4  2003/12/17 11:32:50  pamela  # Revision 3.4  2003/12/17 11:32:50  pamela
33  # CALO SIMULATION COMPLETED: geometry and special tracking parameters updated and simulation checked by a comparison with the Trieste's standalone Monte Carlo simulation  # CALO SIMULATION COMPLETED: geometry and special tracking parameters updated and simulation checked by a comparison with the Trieste's standalone Monte Carlo simulation
34  #  #
# Line 28  Line 55 
55  #CMZ :  1.00/01 28/11/95  18.51.23  by  Francesco Cafagna  #CMZ :  1.00/01 28/11/95  18.51.23  by  Francesco Cafagna
56  #-- Author :    Francesco Cafagna   28/11/95  #-- Author :    Francesco Cafagna   28/11/95
57    
58    June 2006, Bari
59    
60    The center of the scintillator planes S22Y (variable ZPAMS22Y in gpdgeo.inc)
61    and S12X (variable ZPAMS12X in gpdgeo.inc) has been positioned at the
62    nominal height as measured in PAMELA (See the document: "Main geometrical
63    parameters of the PAMELA sub-detectors" by O. Adriani, L. Bonechi,
64    E. Mocchiutti, S. Ricciarini, 20 December 2005). Follows that the positions
65    of S21Y and S12X are higher than those in the cited document due to the fact
66    that in GPAMELA the thickness of the mylar has been considered while in the
67    document it has been neglected.
68    
69    
70    May 2006, Bari & Tor Vergata
71    
72    GIGANTIC RESONANCE FOR NEUTRON DETECTOR ADDED
73    
74       Routines to simulate the gigantic resonance of gammas in Tungsten
75       have been added.  The GPGIG routine is called in GUSTEP if a gamma
76       enter the calorimeter absorber.  This is the steering routine to
77       simulate the production of neutrons from gigantic resonance.  It
78       does checks on STEP lenght. If the range is smaller than the other
79       selected for that step, it does generate the neutron and stops the
80       gamma. Please note that the neutron has now a new particle
81       number. This is to tag the gigantic resonance neutrons.
82    
83    
84    May 2006, Bari & Florence
85    
86    CAL HIT STRUCTURE BUGS FIXED
87    
88       The maximum number of hit is now different for the two hit
89       structures: CALST and CALI. Vectors inizialization and HBOOK
90       ntple booking have been updated. The GPDCAL routine has been fixed
91       so to handle the case in wich hits stored are more than the maximum
92       number of hit.
93       In this case in the ntple up to the maximum number of hits will be stored.
94    
95    April 2006, Bari
96    
97    TOF GEOMETRY AND POSITIONS UPDATED AND NEW MIXTURES ADDED
98    
99       The TOF geometry has been modified. The following boxes have been
100       added: POL1, POL2 and POLY made of polystyrene, S11M, S12M, S21M,
101       S22M, S31M and S32M made of mylar, S1A, S2A and S3 made of air and
102       S1 and S2 made of aluminum. Each scintillator paddle has been put
103       in his mylar box and the other materials: air, polystyrene, and
104       aluminum have been added at their nominal positions.  According to
105       Naples people the araldite glue has been simulated has an air
106       gap. For this work two new materials: the Mylar (MYLAR) and the
107       polystyrene (POLYSTYRENE) with a density of 35 g/l have been
108       defined as a mixture.  The positions of the three bottom
109       scintillator planes that contain respectively the S12X, S22Y and
110       S32X paddles have been regulated according on their official
111       positions in PAMELA.
112    
113    Mar 2006, Bari
114    
115    GEN DATA CARD UPDATED
116    
117       To enable generation on a surface perpendicular to the XY plane,
118       GEN gata card has been updated addingh a new parameter: ZDGEN. This is
119       the dimension, along Z axis , of the generation surface. The Z
120       position will be randomply chosen according to: Z= ZDGEN*RNDM_NUMBER +
121       ZGEN, i.e. Z= GEN(6)*RNDM_NOMBER + GEN(3).
122    
123    Nov 2005, Bari
124    
125    GUHADR AND GUPHAD UPDATED
126    
127       To use GCALOR package the hadronic routines have been updated. The
128       inizialization routine call CALSIG, while the other calls GCALOR.
129    
130    NEW GPKEY ADDED: GPCALOR
131    
132       This logical has been added to enable the GCALOR package. This flag
133       is set to true in GPDAT if the data card: HPAK, is set to
134       'GCAL'. The gpkey.inc has been update accordingly.
135    
136      
137    NEUTRON DETECTOR ADDED. NEW DIR: GPND
138    
139       The neutron detector has been added. At the moment it is just the
140       geometry. The directory structure of the repository has been
141       updated as well. Dimensions has been taken from picture and
142       literature. A full upgrade to the drawing is needed.
143    
144    GCALOR PACKAGE ADDED. NEW DIRs: GPCALOR, GPCALORDES
145    
146       GCALOR package contins the CALOR simulation code and an interface
147       to use it in GEANT. The important feature for us is the usage of
148       the MICAP code. This is facused on the low energy neutron
149       simulation. for details see:
150       http://www.staff.uni-mainz.de/zeitnitz/Gcalor/gcalor.html
151       This package should be distributed with the GEANT library but is
152       not up to date. I did download the latest release and stored into
153       gpcalor directory of the gpamela tree.
154       Then I did clean up the code substituting the explicit inclusion of
155       the commons with a #include cpp directive. In parallel I did
156       extract the commons to include files having the same common name. I
157       did store the include files into a newly created directory:
158       gpcalordes.
159       The Makefile has been updated accordingly.
160       Please note that to avoid conflict with CRENLIB distribution the gcalor source file has been named gpcalor.F
161       NOTE: There are still problem due to different common sizes. In
162       particular the common MICFIL is maller in the geant library
163       libgeant.a . There the subroutines: gmorin, gmxsec, gmplxs, are
164       present and linked using a wrong version of the common. This still needs to be debuged.
165       NOTE2: The auxiliary files with the cross sections: chetc.dat.gz
166       and xsneut.dat.gz, have been added to the aux directory and moved
167       to the working directory, i.e. GPAMELA_BIN. The GCALOR routine will
168       look for CERN_ROOT environment variable. If found files are
169       searched there at first, then in the working directory. A fool
170       proof policy has to be implemented to avoid problem with
171       synchronization fo these files.
172      
173    
174    The GCALOR package
175    
176    June 2005, Bari
177    
178    TOF SCINTILLATOR PADDLES UPDATED
179    
180       The dimensions and the number of the scintillator paddles for each
181       TOF planes have been updated.
182    
183    May 2005, Bari
184    
185    Some updates on the latest modification done in the past year.
186    
187    NEW DATA CARD ADDED: HFSF
188    
189       To define a policy for the random number initial seeds
190       definition. Using this card is possible to override GEANT seeds
191       defined via NRDM card. The policy is selected according to the
192       values:
193    
194       - 1: The seeds are initialized to the initial values found in a user
195            defined file or the default file: INPUTSEED.DAT
196      
197       - 2: The seeds are initialized to the final values found in a user defined
198            file or the default file: INPUTSEED.DAT
199    
200       The case 1 must be used in case the user needs to reproduce the
201       random chain of a previous run. In this case the user can save the
202       initial seeds, used in the run he would like to reproduce, in a
203       binary file and pass the filename to the program using the *FLSF
204       data card. In case the user file is not specified the default
205       INPUTSEED.DAT will be used.
206      
207       The case 2 must be used in case the user needs to chain several
208       GPAMELA run and likes to be sure he is starting the random
209       generator using the right sequence. In this case the user must
210       specify an input binary file using the *FLSF data card, otherwise
211       the INPUTSEED.DAT file will be used.
212    
213    NEW DATA CARD ADDED: *FSFI
214    
215       Using this card the user can specify the logical unit and name of
216       the file storing the initial seeds to be used to initialize the
217       random number generator. This file must be a FORTRAN binary one
218       storing four integer numbers. The first two are the number to be
219       used in the case: HFSF=1, the other two will be used in the case:
220       HFSF=2. This file can be one created by GPAMELA or by the user
221       filled with his own seeds. For this purpose an utility program:
222       writeseeds.f, has been added in the aux directory.  In case the
223       *FSFI card is not specified the default values: 24 and INPUTSEEDS.DAT, will
224       be used as LUN and file name respectively.
225      
226    NEW DATA CARD ADDED: *LSFI
227    
228       Using this card the user can specify the logical unit and name of
229       the file storing the first and last seeds used in the GPAMELA
230       run. This file is a FORTRAN binary one. This file can be used as
231       input one specifying it in the *FSFI data card of the next GPAMELA
232       run.  In case the *LSFI card is not specified the default values: 26
233       and HBOOKFILENAME.DAT (as sepified in *HFI), will be used as LUN
234       and file name respectively.
235      
236    NEW UTILITY PROGRAMS ADDED: writeseeds.f, readseeds.f
237    
238       These new programs have been added in the aux directory. Using these a
239       user defined seed file can be created and re-read.
240    
241    NEW VOLUMES ADDED: MSHE, BSPH; PRESSURIZED CONTAINER ADDED
242    
243       Alexey Bakaldin, in MEPHI, did add the PAMELA pressurized container to
244       the simulation. He did defined new volumes filled with aluminum and
245       placed inside the mother volume. Positions have been fine tuned by
246       Marialuigia Ambriola and compared to the CAD drawings.
247       Two new volumes have been added to simulate the container:
248       - MSHE, a tube simulating the middle part of the container
249       - BSPH, the spherical bottom part of the container
250    
251       To better simulate the upper part the SHEL volume has been modified
252       into a cone. Dimentions of the top cover: TSPH, have been modified
253       accordingly.
254    
255    DETECTOR POSITIONS REVIEWED
256    
257       All detector Z positions have been reviewd to fit into the
258       simulated pressurized container.
259    
260    TRD GEOMETRY AND CALIBRATION REVIEWD
261    
262       The TRD geometry has been deeply reviewed. Using the CAD drawings
263       the carbon fiber frames have been simulated and radiator dimentions
264       corrected. For this reason the calibration done on the beam tests
265       has been revied and new sets of calibration constants calculated
266       comparing the beam test data with the GPAMELA results. The new
267       constants are about 3% larger than the previous ones.
268      
269    TRACKER GEOMETRY REVIEWED. NEW VOLUME DEFINED: THBP, TPAS, TPAI
270      
271       Thanks to Lorenzo Bonechi for the drawings and explanations. Now the
272       hybrd cards have been put into the simulation and the geometry updated
273       considering the dead zones in the silicon detectors. The hybrid zone
274       has been simulated as well. At the moment the hybrid is simulated as
275       a G10 plates. The full height of the tracker magnet has been
276       reviewed as well.
277    
278       The tracker ladder is now simulated inside a nitrogen box: TPAS,
279       placed inside an aluminum frame: TRPB. Each silicon ladder has been
280       simulated using two silicon blocks: TRSL, into each of this block a
281       smaller silicon detector: TPAI, has been placed inside the larger
282       silicon block TRSL. In this way the subdivided silicon ladder can
283       be upgraded with an indipendend roto-translation for each sensor.
284      
285       The TRPB aluminum frame has been enlarged to fit the external
286       magnet canister frame.
287      
288       The last plane has been flipped with a 180 degree rotation around
289       the X axis.
290      
291    TRACKER HIT STRUCTURE REVIEWED
292    
293       Taking into account the new version of the tracker geometry, the hit
294       structure for this detector has been revied.
295    
296    CALORIMETER GEOMETRY REVIEWED
297    
298       Marco Albi reviewed the calorimeter dimentions and positioning.
299    
300    
301  29 March 2004, Bari  29 March 2004, Bari
302    
303  NON-REPRODUCIBILITY PROBLEM OF A GPAMELA RUN FIXED.  NON-REPRODUCIBILITY PROBLEM OF A GPAMELA RUN FIXED.
304  The non-reproducibility of a GPAMELA run was due to the random number     The non-reproducibility of a GPAMELA run was due to the random number
305  initialization in the GARFIELD code. In GARFIELD by default, the initial     initialization in the GARFIELD code. In GARFIELD by default, the initial
306  seeds of the random number generators are always the same while the random     seeds of the random number generators are always the same while the random
307  number generators are called a given number of times (determined by the     number generators are called a given number of times (determined by the
308  hour of the day) during the initialization phase (see init.f subroutine in     hour of the day) during the initialization phase (see init.f subroutine in
309  the GARFIELD code for details). Follows that different runs produce     the GARFIELD code for details). Follows that different runs produce
310  different results without changing the initial seeds. To have identical     different results without changing the initial seeds. To have identical
311  results in different runs, the GARFIELD program has to start typing the     results in different runs, the GARFIELD program has to start typing the
312  noRNDM_initialisation switch. To avoid of specifying this switch by the user,     noRNDM_initialisation switch. To avoid of specifying this switch
313  the GARFIELD package has been upgraded with a patch. In this way the problem     by the user,
314  is partially solved because, now, the initial seeds of the random generators     the GARFIELD package has been upgraded with a patch. In this way the problem
315  in GARFIELD will be always the same even if the RNDM GEANT data card is     is partially solved because, now, the initial seeds of the random generators
316  activated by the user for changing the initial seeds in the GPAMELA program.     in GARFIELD will be always the same even if the RNDM GEANT data card is
317  Work is in progress for a more general correction of this problem.     activated by the user for changing the initial seeds in the GPAMELA program.
318  Please, use the updated GARFIELD code released with the CVS version v4r1     Work is in progress for a more general correction of this problem.
319  to fix this problem.       Please, use the updated GARFIELD code released with the CVS version v4r1
320       to fix this problem.  
321    
322    
323  RNDM ROUTINE REPLACED BY THE GRNDM ROUTINE IN GPXTR AND NPOISS.  RNDM ROUTINE REPLACED BY THE GRNDM ROUTINE IN GPXTR AND NPOISS.
324  The obsolete RNDM random number generator has been replaced by the GEANT     The obsolete RNDM random number generator has been replaced by the GEANT
325  GRNDN routine in the gpxtr.F subroutine and in the npoiss.F function.     GRNDN routine in the gpxtr.F subroutine and in the npoiss.F function.
326    
327  BUG FOUND AND FIXED: the set and detector calorimeter addresses (ISCAL  BUG FOUND AND FIXED: the set and detector calorimeter addresses (ISCAL
328  and IDCASI variables) used in GUTREV were respectively set to a fixed     and IDCASI variables) used in GUTREV were respectively set to a fixed
329  values of 12 and 1. The correct values of these variables are stored in     values of 12 and 1. The correct values of these variables are stored in
330  the GPSED common when the set and the detector ZEBRA banks are filled     the GPSED common when the set and the detector ZEBRA banks are filled
331  during a run. In general the values of the set and detector addresses     during a run. In general the values of the set and detector addresses
332  depend on the number of active detectors in a given run. ISCAL=12 and     depend on the number of active detectors in a given run. ISCAL=12 and
333  IDCASI=1 are only right when all the detectors of GPAMELA are active.     IDCASI=1 are only right when all the detectors of GPAMELA are active.
334    
335  9 December 2003, Bari  9 December 2003, Bari
336    
337  CALORIMETER SIMULATION completed! The update of the geometry and of the     CALORIMETER SIMULATION completed! The update of the geometry and of the
338  special tracking parameters and the tuning of the calorimeter have been     special tracking parameters and the tuning of the calorimeter have been
339  successfully done. A great quantity of simulated data have been produced     successfully done. A great quantity of simulated data have been produced
340  in the calorimeter for different particles (muons, electrons and pions)     in the calorimeter for different particles (muons, electrons and pions)
341  and momenta (5 and 40 GeV/c) and the output data have been analyzed. The     and momenta (5 and 40 GeV/c) and the output data have been analyzed. The
342  distributions of the total energy deposited in the calorimeter and the     distributions of the total energy deposited in the calorimeter and the
343  total number of strips hit have been compared with the respective     total number of strips hit have been compared with the respective
344  distributions produced by the Trieste's tuned standalone Monte Carlo     distributions produced by the Trieste's tuned standalone Monte Carlo
345  simulation program of the PAMELA calorimeter. The accord between the     simulation program of the PAMELA calorimeter. The accord between the
346  two simulations is excellent. Many thanks to Mirko for his collaboration.     two simulations is excellent. Many thanks to Mirko for his collaboration.
347    
348  Working in progress on TRD. The GARFIELD interface to the HEED program is not     Working in progress on TRD. The GARFIELD interface to the HEED program is not
349  optimized to track particle with a charge greater than one and photons. The     optimized to track particle with a charge greater than one and photons. The
350  program print a warning message to advise the user when it is the case.     program print a warning message to advise the user when it is the case.
351    
352  18 April 2003, Bari  18 April 2003, Bari
353    
354  The buffer size of each column of the GPAMELA Ntuple has been increased to     The buffer size of each column of the GPAMELA Ntuple has been increased to
355  4096 and set equal to the record length, defined by a call to the HROPEN     4096 and set equal to the record length, defined by a call to the HROPEN
356  routine.     routine.
357  Also the length of the common /PAWC/ (parameter NWPAW) has been increased     Also the length of the common /PAWC/ (parameter NWPAW) has been increased
358  to 1.34E8, according to the rule that it has to be larger than the number     to 1.34E8, according to the rule that it has to be larger than the number
359  of columns times the buffer size.     of columns times the buffer size.
360    
361  10 April 2003, Bari  10 April 2003, Bari
362    
363  The variables in the HIT STRUCTURE of the CALORIMETER and their way to be     The variables in the HIT STRUCTURE of the CALORIMETER and their way to be
364  filled have been changed according to the electronics system of the real     filled have been changed according to the electronics system of the real
365  detector. In fact, because each silicon detector (module) consists of     detector. In fact, because each silicon detector (module) consists of
366  32 strips and each strip is connected to those belonging to the two detectors     32 strips and each strip is connected to those belonging to the two detectors
367  of the same row (or column) for forming 24 cm long strips, the sum of the     of the same row (or column) for forming 24 cm long strips, the sum of the
368  deposited energies in the strips forming a `long strip' is now calculated for     deposited energies in the strips forming a `long strip' is now calculated for
369  each event (gpucal.F subroutine) and it is stored in a hit only at the     each event (gpucal.F subroutine) and it is stored in a hit only at the
370  end of the event (gutrev.F subroutine).     end of the event (gutrev.F subroutine).
371  The output variables of the GPAMELA en-tuple are then filled in the vectors     The output variables of the GPAMELA en-tuple are then filled in the vectors
372  ICAPLANE(NTHCAL), ICASTRIP(NTHCAL), ENESTRIP(NTHCAL) and ICAMOD(NTHCAL),     ICAPLANE(NTHCAL), ICASTRIP(NTHCAL), ENESTRIP(NTHCAL) and ICAMOD(NTHCAL),
373  by a call to the GPDCAL subroutine:     by a call to the GPDCAL subroutine:
374  -ICAPLANE(i) contains the number of hit plane;     -ICAPLANE(i) contains the number of hit plane;
375  -ICASTRIP(i) contains the number of hit strip;     -ICASTRIP(i) contains the number of hit strip;
376  -ICAMOD(i) can assume different values based on the number of times and     -ICAMOD(i) can assume different values based on the number of times and
377             positions in which a `long strip' has been hit.                positions in which a `long strip' has been hit.
378  -ENESTRIP(i) contains the deposited energy in the hit strip;     -ENESTRIP(i) contains the deposited energy in the hit strip;
379  where i is the number of hit (1<i<4224).     where i is the number of hit (1<i<4224).
380  Note that in the calorimeter each hit is filled at the end of the event and     Note that in the calorimeter each hit is filled at the end of the event and
381  that there is a hit for each `long strip' hit from     that there is a hit for each `long strip' hit from
382  the particle. This use of the hit structure is different for the other     the particle. This use of the hit structure is different for the other
383  detectors and it has been considered to avoid a too big number of hit in the     detectors and it has been considered to avoid a too big number of hit in the
384  calorimeter due to the showers. Follows that NTHCAL, which is the     calorimeter due to the showers. Follows that NTHCAL, which is the
385  max number of hit in the calorimeter, is equal to 4224, the total     max number of hit in the calorimeter, is equal to 4224, the total
386  number of `long strips'. So, for each event, the real number of hit will     number of `long strips'. So, for each event, the real number of hit will
387  be less or equal to 4224.     be less or equal to 4224.
388  ICAMOD(i) is an additional information that does not exist in the real     ICAMOD(i) is an additional information that does not exist in the real
389  detector: if the strip i (i=1,32) of the module 1 or 2 or 3     detector: if the strip i (i=1,32) of the module 1 or 2 or 3
390  is hit, the value of ICAMOD(i) is respectively incremented of 1, 100, 10000.     is hit, the value of ICAMOD(i) is respectively incremented of 1, 100, 10000.
391  Analogously it is done, if it is the strip j (j=33,64) of the modules 4, 5     Analogously it is done, if it is the strip j (j=33,64) of the modules 4, 5
392  and 6 or if it is the strip k (k=65,96) of the modules 7, 8 and 9.     and 6 or if it is the strip k (k=65,96) of the modules 7, 8 and 9.
393  For example if we consider the hit 1 of an event, we could read:     For example if we consider the hit 1 of an event, we could read:
394  ICASTRIP(1)=30, ICAPLANE(1)=21, ENESTRIP(1)=0.5E-03 and ICAMOD(1)=10001.     ICASTRIP(1)=30, ICAPLANE(1)=21, ENESTRIP(1)=0.5E-03 and ICAMOD(1)=10001.
395  It means that the hit 1 contains the information that in the strip 30 of the     It means that the hit 1 contains the information that in the strip 30 of the
396  plane 21 has been deposited a total energy of 0.5E-03 GeV. In addition the     plane 21 has been deposited a total energy of 0.5E-03 GeV. In addition the
397  `long strip 30' has been hit two times, one in the first module and the     `long strip 30' has been hit two times, one in the first module and the
398  other in the third one.     other in the third one.
399    
400  The energy deposited in the calorimeter is calculated in GeV.     The energy deposited in the calorimeter is calculated in GeV.
401    
402  To store the hits in the calorimeter the subroutine GSAHIT is used instead of     To store the hits in the calorimeter the subroutine GSAHIT is used instead of
403  GSCHIT.     GSCHIT.
404    
405  To retrieve the hit structure the call to the routine GPRHIT is done instead     To retrieve the hit structure the call to the routine GPRHIT is done instead
406  of a call to the GFHITS subroutine.     of a call to the GFHITS subroutine.
407    
408  25 February 2003, Bari  25 February 2003, Bari
409    
410  BUG found:  BUG found:
411  DCUTEAER, DCUTEAL, DCUTECE, DCUTECP, DCUTEFE, DCUTEG10C, DCUTEG10, DCUTEKAP,     DCUTEAER, DCUTEAL, DCUTECE, DCUTECP, DCUTEFE, DCUTEG10C, DCUTEG10, DCUTEKAP,
412  DCUTEN2G, DCUTEROA, DCUTESCIN, DCUTESICA, DCUTETRAD, DCUTEW2,     DCUTEN2G, DCUTEROA, DCUTESCIN, DCUTESICA, DCUTETRAD, DCUTEW2,
413  DCUTEW, DCUTEXE variables missed in the commons: gpaer.inc, gpal.inc, gpce.inc,     DCUTEW, DCUTEXE variables missed in the commons: gpaer.inc, gpal.inc, gpce.inc,
414  gpcp.inc, gpfe.inc, gpg10c.inc, gpg10.inc, gpkap.inc, gpn2g.inc, gproa.inc,     gpcp.inc, gpfe.inc, gpg10c.inc, gpg10.inc, gpkap.inc, gpn2g.inc, gproa.inc,
415  gpscin.inc (obsolete), gpscint.inc, gpsica.inc, gptrad.inc, gpw2.inc, gpw.inc,     gpscin.inc (obsolete), gpscint.inc, gpsica.inc, gptrad.inc, gpw2.inc, gpw.inc,
416  gpxe.inc, gpdaer.inc, gpdal.inc, gpdce.inc, gpdcp.inc, gpdfe.inc, gpdg10c.inc,     gpxe.inc, gpdaer.inc, gpdal.inc, gpdce.inc, gpdcp.inc, gpdfe.inc, gpdg10c.inc,
417  gpdg10.inc, gpdkap.inc, gpdn2g.inc, gpdroa.inc, gpdscin.inc, gpdsica.inc,     gpdg10.inc, gpdkap.inc, gpdn2g.inc, gpdroa.inc, gpdscin.inc, gpdsica.inc,
418  gpdtrad.inc, gpdw2.inc, gpdw.inc, gpdxe.inc.     gpdtrad.inc, gpdw2.inc, gpdw.inc, gpdxe.inc.
419  They have been added in these commons and they have been initialized in the     They have been added in these commons and they have been initialized in the
420  GPSTM subroutine.     GPSTM subroutine.
421    
422  Updated the special tracking parameters SICALO, TUNGA, KAOLINITE and G10C     Updated the special tracking parameters SICALO, TUNGA, KAOLINITE and G10C
423  in the subroutines gpsica.F, gpw2.F, gpw.F, gpce.F and gpg10c.F. They were     in the subroutines gpsica.F, gpw2.F, gpw.F, gpce.F and gpg10c.F. They were
424  suggested by Mirko Boezio.     suggested by Mirko Boezio.
425    
426  Updated the value of the absorption length for silicon in the calorimeter     Updated the value of the absorption length for silicon in the calorimeter
427  and tracker although this parameter is ignored by GEANT. For this reason     and tracker although this parameter is ignored by GEANT. For this reason
428  it was equal to the radiation length.     it was equal to the radiation length.
429    
430  Updated the relative positions of the calorimeter planes. The corrected     Updated the relative positions of the calorimeter planes. The corrected
431  shifting are:     shifting are:
432    
433  first view: (Dxo,Dyo)=(0.10,0.05) cm     first view: (Dxo,Dyo)=(0.10,0.05) cm
434  second view: (Dxo,Dyo)=(-0.05,0.10) cm     second view: (Dxo,Dyo)=(-0.05,0.10) cm
435  third view: (Dxo,Dyo)=(-0.10,-0.05) cm     third view: (Dxo,Dyo)=(-0.10,-0.05) cm
436  fourth view: (Dxo,Dyo)=(0.05,-0.10) cm     fourth view: (Dxo,Dyo)=(0.05,-0.10) cm
437    
438  4 November 2002, Bari  4 November 2002, Bari
439    
440  CAS detectors distances modified  CAS detectors distances modified
441    
442  The distances between the CAS detectors have been modified based on the     The distances between the CAS detectors have been modified based on the
443  latest CAD drawings.     latest CAD drawings.
444    
445  2 November 2002, Bari  2 November 2002, Bari
446    
447  CALORIMETER geometry upgrade  CALORIMETER geometry upgrade
448    
449  The volumes CAPD and CAAD have been taken off from the calorimeter.     The volumes CAPD and CAAD have been taken off from the calorimeter.
450  In addition the logical tree has been slightly changed to make the shifts of     In addition the logical tree has been slightly changed to make the shifts of
451  the silicon planes into the calorimeter box easier, i.e. the CAPL volume,     the silicon planes into the calorimeter box easier, i.e. the CAPL volume,
452  which was made of the CASI, CAKP, CAGL, C10C and CAKA volumes, has     which was made of the CASI, CAKP, CAGL, C10C and CAKA volumes, has
453  been split up in the volumes CANS and CAPL. Now CANS is made of the CAKP,     been split up in the volumes CANS and CAPL. Now CANS is made of the CAKP,
454  CAGL, C10C and CAKA volumes while CAPL contains the CASI volume, that has to     CAGL, C10C and CAKA volumes while CAPL contains the CASI volume, that has to
455  be shifted as a function of the vertical position in the calorimeter. Also the     be shifted as a function of the vertical position in the calorimeter. Also the
456  dimensions of some volumes have been upgraded, including the external ones:     dimensions of some volumes have been upgraded, including the external ones:
457  CALB and CALS. CALS is an aluminum box of dimensions: 48.4*48.4*21.278 cm^3,     CALB and CALS. CALS is an aluminum box of dimensions: 48.4*48.4*21.278 cm^3,
458  having side-walls 1 cm thick and a bottom of 1 mm. The real box is more     having side-walls 1 cm thick and a bottom of 1 mm. The real box is more
459  complicated and the configuration of the bottom should be upgraded if we want     complicated and the configuration of the bottom should be upgraded if we want
460  a reliable description of the event in the S4 scintillator.     a reliable description of the event in the S4 scintillator.
461    
462  22 October 2002, Stockholm  22 October 2002, Stockholm
463    

Legend:
Removed from v.3.5  
changed lines
  Added in v.3.14

  ViewVC Help
Powered by ViewVC 1.1.23