--- gpamela/history/v_100.txt 2002/07/11 16:01:59 3.1 +++ gpamela/history/v_100.txt 2002/12/05 10:17:42 3.2 @@ -1,7 +1,10 @@ # -# $Id$ +# $Id: v_100.txt,v 3.1.1.1 2002/07/11 16:01:59 cafagna Exp $ +# +# $Log: v_100.txt,v $ +# Revision 3.1.1.1 2002/07/11 16:01:59 cafagna +# First GPAMELA release on CVS # -# $Log$ # #CMZ : 3.00/00 11/02/2002 20.05.23 by Unknown #CMZ : 2.03/00 06/11/2000 02.14.56 by Francesco Cafagna @@ -15,6 +18,45 @@ #CMZ : 1.00/02 05/04/96 15.31.25 by Francesco Cafagna #CMZ : 1.00/01 28/11/95 18.51.23 by Francesco Cafagna #-- Author : Francesco Cafagna 28/11/95 + +4 November 2002, Bari + +CAS detectors distances modified + +The distances between the CAS detectors has been modified based on the +latest CAD drawings. + +2 November 2002, Bari + +CALORIMETER geometry upgrade + +The volumes CAPD and CAAD have been taken off from the calorimeter. +In addition the logical tree has been slightly changed to make the shifts of +the silicon planes into the calorimeter box easier, i.e. the CAPL volume, +which was made of the CASI, CAKP, CAGL, C10C and CAKA volumes, has +been split up in the volumes CANS and CAPL. Now CANS is made of the CAKP, +CAGL, C10C and CAKA volumes while CAPL contains the CASI volume, that has to +be shifted as a function of the vertical position in the calorimeter. Also the +dimensions of some volumes have been upgraded, including the external ones: +CALB and CALS. CALS is an aluminum box of dimensions: 48.4*48.4*21.278 cm^3, +having side-walls 1 cm thick and a bottom of 1 mm. The real box is more +complicated and the configuration of the bottom should be upgraded if we want +a reliable description of the event in the S4 scintillator. + +22 October 2002, Stockholm + +ANTICOINC. GEOMETRY UPGRADE + + The AC geometry has been updated. The top AC scintillator (CAT) now + consists of 1 single sheet of scintillator with a hole in the middle + and the correct geometry(*). The side AC scintillators (CAS) also + have the correct shape. The AC scintillators are placed in aluminum + boxes with plastic rims inside. For these rims a 'new' material, PLAS, + was defined. PLAS has all the characteristics of SCIN but is + non-sensitive. No PMTs or PMT holders have been modelled. + (*)-The interfaces on CAT where the PMTs should be located are + slightly different from the real case. + 11 February 2002, Bari MACRO CLEAN-UP