1 |
# |
# |
2 |
# $Id: v_100.txt,v 3.12 2006/05/18 10:52:32 pam-ba Exp $ |
# $Id: v_100.txt,v 3.21 2006/11/28 10:26:15 pam-ba Exp $ |
3 |
# |
# |
4 |
# $Log: v_100.txt,v $ |
# $Log: v_100.txt,v $ |
5 |
|
# Revision 3.21 2006/11/28 10:26:15 pam-ba |
6 |
|
# S3 positioning completed |
7 |
|
# |
8 |
|
# Revision 3.20 2006/11/16 18:45:29 pam-ba |
9 |
|
# Simulated an aluminum container for S4 |
10 |
|
# |
11 |
|
# Revision 3.19 2006/11/16 12:01:13 pam-ba |
12 |
|
# S4 dimensions corrected. |
13 |
|
# |
14 |
|
# Revision 3.18 2006/11/10 11:39:35 pam-ba |
15 |
|
# S2 and S1 z-positions corrected, He3 and plystyrene mixture added, Top Plate geometry simulated and titanium mixture added. |
16 |
|
# |
17 |
|
# Revision 3.17 2006/10/13 16:36:59 pam-ba |
18 |
|
# Added a new material, the cadmium, for ND |
19 |
|
# |
20 |
|
# Revision 3.16 2006/10/12 11:11:21 pam-ba |
21 |
|
# ND geometry updated. |
22 |
|
# |
23 |
|
# Revision 3.15 2006/10/02 11:17:30 pam-ba |
24 |
|
# NDET 'SPHE' data card meaning changed. Now it eliminates the whole PAMELA container. |
25 |
|
# |
26 |
|
# Revision 3.14 2006/06/30 15:38:16 pam-ba |
27 |
|
# S22 and S12 heights positioned in GPAMELA at the nominal heights in PAMELA (see document: Main geometrical parameters of the PAMELA sub-detectors, 20 December 2005) |
28 |
|
# |
29 |
|
# Revision 3.13 2006/06/05 13:56:17 pamela |
30 |
|
# Gigantic resonance added for gamma enetering in the calorimeter absorber |
31 |
|
# |
32 |
# Revision 3.12 2006/05/18 10:52:32 pam-ba |
# Revision 3.12 2006/05/18 10:52:32 pam-ba |
33 |
# TOF geometry completed and a new material, the polystyrene (density 35 g/l), added |
# TOF geometry completed and a new material, the polystyrene (density 35 g/l), added |
34 |
# |
# |
79 |
#CMZ : 1.00/01 28/11/95 18.51.23 by Francesco Cafagna |
#CMZ : 1.00/01 28/11/95 18.51.23 by Francesco Cafagna |
80 |
#-- Author : Francesco Cafagna 28/11/95 |
#-- Author : Francesco Cafagna 28/11/95 |
81 |
|
|
82 |
|
November 2006, Bari |
83 |
|
|
84 |
|
|
85 |
|
S4 GEOMETRY UPDATED: |
86 |
|
The x and y dimensions have been corrected because they were wrong. |
87 |
|
A container of aluminum has been added having walls of thickness equal |
88 |
|
to 0.1 cm. |
89 |
|
|
90 |
|
TOF POSITIONS DEFINITELY UPDATED: |
91 |
|
S2 and S1 have been positioned again, after the simulation of the top plate. |
92 |
|
Before now, the positions were put by hand based on the positions given by |
93 |
|
Sergio Ricciarini in the document 'Main geometrical parameters of the PAMELA |
94 |
|
sub-detectors' released by O. Adriani, L. Bonechi, E. Mocchiutti and |
95 |
|
S. Ricciarini on the 20th of December 2005.. These positions were |
96 |
|
lightly approximated because the thicknesses of the mylar and of the glue were |
97 |
|
not considered in that document. Also the height of S3 has been modified as |
98 |
|
suggested from the Naples PAMELA collaborators. |
99 |
|
|
100 |
|
ND GEOMETRY COMPLETED. |
101 |
|
The He3 and the polyethylene (CH2) have been added to fill |
102 |
|
the volumes NDTI and NDPB in the neutron detector. Leonov gave us the |
103 |
|
details of these materials. |
104 |
|
|
105 |
|
TOP PLATE GEOMETRY ADDED. |
106 |
|
The top plate geometry has been simulated as a rectangular window filled |
107 |
|
with a mixture of titanium (90%), aluminum (6%) and vanadium (4%). It has been |
108 |
|
put in a N2 box having the same planar dimensions of CATA. In this box there |
109 |
|
are also S2 and CATA at the right positions. Then the top plate geometry has |
110 |
|
been completed with other eight small volumes of titanium positioned at the |
111 |
|
corners of the N2 box. Four of them are at the same height of CATA, the |
112 |
|
other four are at the same height of S2. The simulated geometry of the top |
113 |
|
plate is based on a simplified version of the CAD drawings. |
114 |
|
|
115 |
|
October 2006, Bari |
116 |
|
|
117 |
|
The geometry of the neutron detector has been updated. Some dimensions of some |
118 |
|
volumes have been corrected and the aluminum cover and the aluminum boxes to |
119 |
|
put the cables have been added. A new material, the cadmium, has been also |
120 |
|
defined. |
121 |
|
|
122 |
|
September 2006, Bari |
123 |
|
|
124 |
|
SPHE and ND data card bugs fixed: the definition of the ND data card, |
125 |
|
missing in the subroutine gpgeo.F, has been added; the meaning of the SPHE |
126 |
|
data card has been changed. Before the correction the data card: |
127 |
|
NDET 'SPHE' was used to delete the spherical top shell to substitute it with |
128 |
|
a flat one.Now NDET 'SPHE' eliminates the whole container of PAMELA. |
129 |
|
|
130 |
|
|
131 |
|
June 2006, Bari |
132 |
|
|
133 |
|
The center of the scintillator planes S22Y (variable ZPAMS22Y in gpdgeo.inc) |
134 |
|
and S12X (variable ZPAMS12X in gpdgeo.inc) has been positioned at the |
135 |
|
nominal height as measured in PAMELA (See the document: "Main geometrical |
136 |
|
parameters of the PAMELA sub-detectors" by O. Adriani, L. Bonechi, |
137 |
|
E. Mocchiutti, S. Ricciarini, 20 December 2005). Follows that the positions |
138 |
|
of S21Y and S12X are higher than those in the cited document due to the fact |
139 |
|
that in GPAMELA the thickness of the mylar has been considered while in the |
140 |
|
document it has been neglected. |
141 |
|
|
142 |
|
|
143 |
May 2006, Bari & Tor Vergata |
May 2006, Bari & Tor Vergata |
144 |
|
|
145 |
GIGANTIC RESONANCE FOR NEUTRON DETECTOR ADDED |
GIGANTIC RESONANCE FOR NEUTRON DETECTOR ADDED |