/[PAMELA software]/gpamela/history/v_100.txt
ViewVC logotype

Diff of /gpamela/history/v_100.txt

Parent Directory Parent Directory | Revision Log Revision Log | View Patch Patch

revision 3.10 by cafagna, Mon Apr 10 11:07:43 2006 UTC revision 3.15 by pam-ba, Mon Oct 2 11:17:30 2006 UTC
# Line 1  Line 1 
   
1  #  #
2  # $Id: v_100.txt,v 3.9 2005/12/14 03:34:40 cafagna Exp $  # $Id: v_100.txt,v 3.14 2006/06/30 15:38:16 pam-ba Exp $
3  #  #
4  # $Log: v_100.txt,v $  # $Log: v_100.txt,v $
5    # Revision 3.14  2006/06/30 15:38:16  pam-ba
6    # S22 and S12 heights positioned in GPAMELA at the nominal heights in PAMELA (see document: Main geometrical parameters of the PAMELA sub-detectors, 20 December 2005)
7    #
8    # Revision 3.13  2006/06/05 13:56:17  pamela
9    # Gigantic resonance added for gamma enetering in the calorimeter absorber
10    #
11    # Revision 3.12  2006/05/18 10:52:32  pam-ba
12    # TOF geometry completed and a new material, the polystyrene (density 35 g/l), added
13    #
14    # Revision 3.11  2006/05/11 23:53:15  cafagna
15    # More bugs fixed in the CALO ntple structure filling
16    #
17    # Revision 3.10  2006/04/10 11:07:43  cafagna
18    # GEN data card updated, ZDGEN added
19    #
20  # Revision 3.9  2005/12/14 03:34:40  cafagna  # Revision 3.9  2005/12/14 03:34:40  cafagna
21  # An update of the history and inform readme files.  # An update of the history and inform readme files.
22  #  #
# Line 44  Line 58 
58  #CMZ :  1.00/01 28/11/95  18.51.23  by  Francesco Cafagna  #CMZ :  1.00/01 28/11/95  18.51.23  by  Francesco Cafagna
59  #-- Author :    Francesco Cafagna   28/11/95  #-- Author :    Francesco Cafagna   28/11/95
60    
61    September 2006, Bari
62    
63    SPHE and ND data card bugs fixed: the definition of the ND data card,
64    missing in the subroutine gpgeo.F, has been added; the meaning of the SPHE
65    data card has been changed. Before the correction the data card:
66    NDET 'SPHE' was used to delete the spherical top shell to substitute it with
67    a flat one.Now NDET 'SPHE' eliminates the whole container of PAMELA.
68    
69    
70    June 2006, Bari
71    
72    The center of the scintillator planes S22Y (variable ZPAMS22Y in gpdgeo.inc)
73    and S12X (variable ZPAMS12X in gpdgeo.inc) has been positioned at the
74    nominal height as measured in PAMELA (See the document: "Main geometrical
75    parameters of the PAMELA sub-detectors" by O. Adriani, L. Bonechi,
76    E. Mocchiutti, S. Ricciarini, 20 December 2005). Follows that the positions
77    of S21Y and S12X are higher than those in the cited document due to the fact
78    that in GPAMELA the thickness of the mylar has been considered while in the
79    document it has been neglected.
80    
81    
82    May 2006, Bari & Tor Vergata
83    
84    GIGANTIC RESONANCE FOR NEUTRON DETECTOR ADDED
85    
86       Routines to simulate the gigantic resonance of gammas in Tungsten
87       have been added.  The GPGIG routine is called in GUSTEP if a gamma
88       enter the calorimeter absorber.  This is the steering routine to
89       simulate the production of neutrons from gigantic resonance.  It
90       does checks on STEP lenght. If the range is smaller than the other
91       selected for that step, it does generate the neutron and stops the
92       gamma. Please note that the neutron has now a new particle
93       number. This is to tag the gigantic resonance neutrons.
94    
95    
96    May 2006, Bari & Florence
97    
98    CAL HIT STRUCTURE BUGS FIXED
99    
100       The maximum number of hit is now different for the two hit
101       structures: CALST and CALI. Vectors inizialization and HBOOK
102       ntple booking have been updated. The GPDCAL routine has been fixed
103       so to handle the case in wich hits stored are more than the maximum
104       number of hit.
105       In this case in the ntple up to the maximum number of hits will be stored.
106    
107    April 2006, Bari
108    
109    TOF GEOMETRY AND POSITIONS UPDATED AND NEW MIXTURES ADDED
110    
111       The TOF geometry has been modified. The following boxes have been
112       added: POL1, POL2 and POLY made of polystyrene, S11M, S12M, S21M,
113       S22M, S31M and S32M made of mylar, S1A, S2A and S3 made of air and
114       S1 and S2 made of aluminum. Each scintillator paddle has been put
115       in his mylar box and the other materials: air, polystyrene, and
116       aluminum have been added at their nominal positions.  According to
117       Naples people the araldite glue has been simulated has an air
118       gap. For this work two new materials: the Mylar (MYLAR) and the
119       polystyrene (POLYSTYRENE) with a density of 35 g/l have been
120       defined as a mixture.  The positions of the three bottom
121       scintillator planes that contain respectively the S12X, S22Y and
122       S32X paddles have been regulated according on their official
123       positions in PAMELA.
124    
125  Mar 2006, Bari  Mar 2006, Bari
126    
127  GEN DATA CARD UPDATED  GEN DATA CARD UPDATED
# Line 106  GCALOR PACKAGE ADDED. NEW DIRs: GPCALOR, Line 184  GCALOR PACKAGE ADDED. NEW DIRs: GPCALOR,
184        
185    
186  The GCALOR package  The GCALOR package
187    
188    June 2005, Bari
189    
190    TOF SCINTILLATOR PADDLES UPDATED
191    
192       The dimensions and the number of the scintillator paddles for each
193       TOF planes have been updated.
194    
195  May 2005, Bari  May 2005, Bari
196    
197  Some updates on the latest modification done in the past year.  Some updates on the latest modification done in the past year.

Legend:
Removed from v.3.10  
changed lines
  Added in v.3.15

  ViewVC Help
Powered by ViewVC 1.1.23