95 |
{\it \bf STANDARD situations:} \\ |
{\it \bf STANDARD situations:} \\ |
96 |
- flat line, in case of a partial RAW data acquisition this is nominal;\\ |
- flat line, in case of a partial RAW data acquisition this is nominal;\\ |
97 |
- ``no dsp infos'', in case of RAW data acquisition this is nominal;\\ |
- ``no dsp infos'', in case of RAW data acquisition this is nominal;\\ |
98 |
- more segments not passing through zero is normal behaviour for different runs. |
- more segments not passing through zero is normal behaviour for different runs.\\ |
99 |
NO ACTIONS to be taken.\\ |
NO ACTIONS to be taken.\\ |
100 |
{\it \bf NON--STANDARD situations:} \\ |
{\it \bf NON--STANDARD situations:} \\ |
101 |
- non linear dependence;\\ |
- non linear dependence;\\ |
160 |
{\it \bf NOMINAL:}\\ |
{\it \bf NOMINAL:}\\ |
161 |
Most of the data should be inside the yellow region.\\ |
Most of the data should be inside the yellow region.\\ |
162 |
{\it \bf STANDARD situations:} \\ |
{\it \bf STANDARD situations:} \\ |
163 |
- The distribution spreads over a larger range of ADC values. The file contains calibrations too distant in time or the calorimeter has just been switched on. |
- The distribution spreads over a larger range of ADC values. The file contains calibrations too distant in time or the calorimeter has just been switched on.\\ |
164 |
- Signal at about 32000 ADC channels. Latch--up in one or more viwes.\\ |
- Signal at about 32000 ADC channels. Latch--up in one or more viwes.\\ |
165 |
ACTION: check after a calibration, if problem persist contact specialist.\\ |
ACTION: check after a calibration, if problem persist contact specialist.\\ |
166 |
{\it \bf NON--STANDARD situations:} \\ |
{\it \bf NON--STANDARD situations:} \\ |
291 |
{\it \bf Description:}\\ |
{\it \bf Description:}\\ |
292 |
Baselines (ADC channels) obtained during a calibration procedure.\\ |
Baselines (ADC channels) obtained during a calibration procedure.\\ |
293 |
{\it \bf NOMINAL:}\\ |
{\it \bf NOMINAL:}\\ |
294 |
Most of values inside yellow region. |
Most of values inside yellow region.\\ |
295 |
{\it \bf STANDARD situations:} \\ |
{\it \bf STANDARD situations:} \\ |
296 |
- some hits outside yellow region;\\ |
- some hits outside yellow region;\\ |
297 |
- about six consecutive values at zero or 32000; latch--up alarm from a plane during calibration?\\ |
- about six consecutive values at zero or 32000; latch--up alarm from a plane during calibration?\\ |