1 |
51: GLTABLES - TO_TIME < time when querying tables |
2 |
-1: Missing/wrong run ID input parameter |
3 |
-2: DB connection failure |
4 |
-3: Error in input parameters (check format) |
5 |
-4: Request reprocessing of all runs (idRun = 0) but processFile is missing |
6 |
-6: No LEVEL0 file |
7 |
-7: No Physics tree in LEVEL0 file |
8 |
-8: No Header branch in LEVEL0 Physics tree |
9 |
-9: No Registry branch in LEVEL0 Physics tree |
10 |
-11: LEVEL0 Physics tree is empty |
11 |
-12: LEVEL2 output directory does not exists |
12 |
-13: Cannot create processFolder directory |
13 |
-14: Error querying the DB |
14 |
-15: Cannot open file for writing |
15 |
// |
16 |
-50: GLTABLES - No entries matching GL_RUN query |
17 |
-51: GLTABLES - No entries matching GL_ROOT query |
18 |
-52: GLTABLES - No entries matching GL_PARAM query |
19 |
-53: GLTABLES - No entries matching GL_TRK_CALIB query |
20 |
-54: GLTABLES - No entries matching GL_CALO_CALIB query |
21 |
-55: GLTABLES - No entries matching GL_CALO_CALIB query |
22 |
// |
23 |
-100: CALORIMETERLEVEL2 - No Level2 input file |
24 |
-101: CALORIMETERLEVEL2 - Cannot open Level2 file |
25 |
-102: CALORIMETERLEVEL2 - No Tracker TTree in Level2 file |
26 |
-103: CALORIMETERLEVEL2 - No Calorimeter TBranch in Level0 file |
27 |
-104: CALORIMETERLEVEL2 - No Trigger TTree in Level0 file |
28 |
-105: CALORIMETERLEVEL2 - No Calorimeter ADC2MIP conversion file |
29 |
-106: CALORIMETERLEVEL2 - No Calorimeter alignement file |
30 |
-107: CALORIMETERLEVEL2 - Cannot find Level0 file needed for the calibration |
31 |
-108: CALORIMETERLEVEL2 - Cannot open Level0 file needed for the calibration |
32 |
-109: CALORIMETERLEVEL2 - No CalibCalPed TTree in Level0 file needed for the calibration |
33 |
-110: CALORIMETERLEVEL2 - No calibrations in Level0 file needed for the calibration |
34 |
-111: CALORIMETERLEVEL2 - Corrupted calibration |
35 |
-112: CALORIMETERLEVEL2 - No physics event related to registry entry in Level0 file |
36 |
-113: CALORIMETERLEVEL2 - No tracker event related to registry entry in Level2 file |
37 |
// |
38 |
-200: TRACKERLEVEL2 - LEVEL1 framework unknown (HBOOK/ROOT) |
39 |
-201: TRACKERLEVEL2 - LEVEL2 framework unknown (HBOOK/ROOT) |
40 |
-202: TRACKERLEVEL2 - Neither LEVEL1 nor LEVEL2 output requested |
41 |
-203: TRACKERLEVEL2 - No Tracker branch in LEVEL0 Physics tree |
42 |
-204: TRACKERLEVEL2 - No reprocessing implemented for LEVEL1 output |
43 |
-205: TRACKERLEVEL2 - Error accessing RunInfo |
44 |
-210: TRACKERLEVEL2 - Error opening/reading trk mask GL_PARAM parameters |
45 |
-211: TRACKERLEVEL2 - Error opening/reading trk alignment GL_PARAM parameters |
46 |
-212: TRACKERLEVEL2 - Error opening/reading trk mip GL_PARAM parameters |
47 |
-213: TRACKERLEVEL2 - Error opening/reading trk charge GL_PARAM parameters |
48 |
-214: TRACKERLEVEL2 - Error opening/reading trk pfa GL_PARAM parameters |
49 |
-215: TRACKERLEVEL2 - Error opening/reading field GL_PARAM parameters |
50 |
-216: TRACKERLEVEL2 - Error opening/reading default calibration GL_PARAM parameters |
51 |
-298: TRACKERLEVEL2 - Reprocessing not implemented in standalone mode |
52 |
-299: TRACKERLEVEL2 - Not yet implemented |
53 |
// |
54 |
-300: TOFLEVEL2 - No Trigger branch in Level0 tree |
55 |
-301: TOFLEVEL2 - Cannot open file for writing |
56 |
-302: TOFLEVEL2 - No tracker tree in Level2 file |
57 |
-303: TOFLEVEL2 - No Tof branch in Level0 file |
58 |
-313: TOFLEVEL2 - No more tracker events in Level2 file |
59 |
// |
60 |
-401: TRIGGERLEVEL2 - Cannot open file for writing |
61 |
-402: TRIGGERLEVEL2 - No Trigger branch in Level0 tree |
62 |
// |
63 |
-500: S4LEVEL2 - No level2 file |
64 |
-501: S4LEVEL2 - Cannot open file for writing |
65 |
-502: S4LEVEL2 - No result from GL_S4_CALIB |
66 |
-503: S4LEVEL2 - No S4 branch in Level0 tree |
67 |
// |
68 |
-600: NDLEVEL2 - No level2 file |
69 |
-601: NDLEVEL2 - Cannot open file for writing |
70 |
-603: NDLEVEL2 - No S4Level2 branch in Level0 tree |
71 |
// |
72 |
-701: NDLEVEL2 - Cannot open file for writing |
73 |
-704: NDLEVEL2 - No Anticounter branch in Level0 tree |
74 |
// |
75 |
-800: RUNINFO - No such run in the RunInfo list |
76 |
-801: RUNINFO - No RunInfo tree in Level2 file |
77 |
-802: RUNINFO - Cannot open file for writing |
78 |
-803: RUNINFO - Updating but no RunInfo tree in Level2 file |
79 |
-804: RUNINFO - Unknown detector |
80 |
// |
81 |
100: CALORIMETERLEVEL2 - Data with no associated calibration |
82 |
101: CALORIMETERLEVEL2 - No tracks or good events in this run |