     51:    GLTABLES - TO_TIME < time when querying tables
     -1:    Missing/wrong run ID input parameter
     -2:    DB connection failure
     -3:    Error in input parameters (check format)
     -4:    Request reprocessing of all runs (idRun = 0) but processFile is missing
     -6:    No LEVEL0 file 
     -7:    No Physics tree in LEVEL0 file
     -8:    No Header branch in LEVEL0 Physics tree
     -9:    No Registry branch in LEVEL0 Physics tree
     -11:   LEVEL0 Physics tree is empty
     -12:   LEVEL2 output directory does not exists
     -13:   Cannot create processFolder directory
     -14:   Error querying the DB
     -15:   Cannot open file for writing
      //
     -50:   GLTABLES - No entries matching GL_RUN query
     -51:   GLTABLES - No entries matching GL_ROOT query
     -52:   GLTABLES - No entries matching GL_PARAM query
     -53:   GLTABLES - No entries matching GL_TRK_CALIB query
     -54:   GLTABLES - No entries matching GL_CALO_CALIB query
     -55:   GLTABLES - No entries matching GL_CALO_CALIB query
      //      
     -100:  CALORIMETERLEVEL2 - No Level2 input file
     -101:  CALORIMETERLEVEL2 -  Cannot open Level2 file
     -102:  CALORIMETERLEVEL2 -  No Tracker TTree in Level2 file
     -103:  CALORIMETERLEVEL2 -  No Calorimeter TBranch in Level0 file
     -104:  CALORIMETERLEVEL2 -  No Trigger TTree in Level0 file
     -105:  CALORIMETERLEVEL2 -  No Calorimeter ADC2MIP conversion file
     -106:  CALORIMETERLEVEL2 -  No Calorimeter alignement file
     -107:  CALORIMETERLEVEL2 -  Cannot find Level0 file needed for the calibration
     -108:  CALORIMETERLEVEL2 -  Cannot open Level0 file needed for the calibration
     -109:  CALORIMETERLEVEL2 -  No CalibCalPed TTree in Level0 file needed for the calibration
     -110:  CALORIMETERLEVEL2 -  No calibrations in Level0 file needed for the calibration
     -111:  CALORIMETERLEVEL2 -  Corrupted calibration
     -112:  CALORIMETERLEVEL2 -  No physics event related to registry entry in Level0 file
     -113:  CALORIMETERLEVEL2 -  No tracker event related to registry entry in Level2 file
      //
     -200:  TRACKERLEVEL2 - LEVEL1 framework unknown (HBOOK/ROOT)
     -201:  TRACKERLEVEL2 - LEVEL2 framework unknown (HBOOK/ROOT)
     -202:  TRACKERLEVEL2 - Neither LEVEL1 nor LEVEL2 output requested
     -203:  TRACKERLEVEL2 - No Tracker branch in LEVEL0 Physics tree
     -204:  TRACKERLEVEL2 - No reprocessing implemented for LEVEL1 output
     -205:  TRACKERLEVEL2 - Error accessing RunInfo 
     -210:  TRACKERLEVEL2 - Error opening/reading trk mask GL_PARAM parameters 
     -211:  TRACKERLEVEL2 - Error opening/reading trk alignment GL_PARAM parameters
     -212:  TRACKERLEVEL2 - Error opening/reading trk mip GL_PARAM parameters
     -213:  TRACKERLEVEL2 - Error opening/reading trk charge GL_PARAM parameters
     -214:  TRACKERLEVEL2 - Error opening/reading trk pfa GL_PARAM parameters
     -215:  TRACKERLEVEL2 - Error opening/reading field GL_PARAM parameters
     -216:  TRACKERLEVEL2 - Error opening/reading default calibration GL_PARAM parameters
     -298:  TRACKERLEVEL2 - Reprocessing not implemented in standalone mode
     -299:  TRACKERLEVEL2 - Not yet implemented
      //
     -300:  TOFLEVEL2 - No Trigger branch in Level0 tree
     -301:  TOFLEVEL2 - Cannot open file for writing
     -302:  TOFLEVEL2 - No tracker tree in Level2 file
     -303:  TOFLEVEL2 - No Tof branch in Level0 file
     -313:  TOFLEVEL2 - No more tracker events in Level2 file
      //
     -401:  TRIGGERLEVEL2 - Cannot open file for writing
     -402:  TRIGGERLEVEL2 - No Trigger branch in Level0 tree
      //
     -500:  S4LEVEL2 - No level2 file
     -501:  S4LEVEL2 - Cannot open file for writing
     -502:  S4LEVEL2 - No result from GL_S4_CALIB
     -503:  S4LEVEL2 - No S4 branch in Level0 tree
      //
     -600:  NDLEVEL2 - No level2 file
     -601:  NDLEVEL2 - Cannot open file for writing
     -603:  NDLEVEL2 - No S4Level2 branch in Level0 tree
      //
     -701:  NDLEVEL2 - Cannot open file for writing
     -704:  NDLEVEL2 - No Anticounter branch in Level0 tree
      //
     -800:  RUNINFO - No such run in the RunInfo list
     -801:  RUNINFO - No RunInfo tree in Level2 file
     -802:  RUNINFO - Cannot open file for writing
     -803:  RUNINFO - Updating but no RunInfo tree in Level2 file
     -804:  RUNINFO - Unknown detector
      //
      100:  CALORIMETERLEVEL2 - Data with no associated calibration
      101:  CALORIMETERLEVEL2 - No tracks or good events in this run